Detail 47298 Control Unit MicroLogic 6.0P, MasterPact NT Drawout, LSIG

Engine Control Unit

Control unit MicroLogic 6.0P, MasterPact NT drawout, LSIG protections

Specifications

Main
Range : MasterPact
Range of product : MasterPact NT
Product or component type : Control unit
Trip unit name : MicroLogic 6.0 P
Trip unit technology : Electronic
Range compatibility : Masterpact NT06...16
Device application : Distribution
Number of poles :
- 3P
- 4P
Protected poles description :
- 4t
- 3t
- 3t + N/2
Trip unit protection functions : Selective + earth-fault protection
Protection type :
- For overload protection (long time)
- for short time short-circuit protection
- for instantaneous short-circuit protection
- for earth fault
Trip unit rating :
- 630 A at 50 °C
- 800 A at 50 °C
- 1000 A at 50 °C
- 1250 A at 50 °C
- 1600 A at 50 °C
Network type : AC
Network frequency : 50/60 Hz
Circuit breaker mounting mode : Drawout

Complementary
Long-time pick-up adjustment type Ir (thermal protection) : Adjustable 9 settings
[Ir] long-time protection pick-up adjustment range : 0.4...1 x In
Long-time protection delay adjustment type tr : Adjustable 9 settings
[tr] long-time protection delay adjustment range :
- 0.7…16.6 s at 7.2 x Ir
- 0.7…24 s at 6 x Ir
- 12.5…600 s at 1.5 x Ir
Thermal memory : 20 mn
Short-time protection pick-up adjustment type Isd : Adjustable 9 settings
[Isd] Short-time protection pick-up adjustment range : 1.5...10 x Ir
Short-time protection delay adjustment type tsd : Adjustable
[tsd] Short-time protection delay adjustment range :
- 0…0.4 s I²t=off
- 0.1…0.4 s I²t=on
Instantaneous protection pick-up adjustment type Ii : Adjustable 9 settings
[Ii] instantaneous protection pick-up adjustment range :
- 2...15 x In
- Off
Ground-fault protection pick-up adjustment type Ig : Adjustable 9 settings
[Ig] ground-fault protection pick-up adjustment range :
- 0.2...1 x In for 400 A < In < 1250 A
- 0.3...1 x In for In <= 400 A
- 500...1200 A for In >= 1250 A
Ground-fault protection time delay adjustment type tg : Adjustable
[tg] ground-fault protection time delay adjustment range :
- 0…0.4 s I²t=off
- 0.1…0.4 s I²t=on
Earth-leakage protection : Without
Zone selective interlocking ZSI : With
Local signalling :
- 3 LEDs (red) for electrical fault
- 1 LED (red) for internal error
Display type : Digital display
type of measurement : Power meter
Communication of data :
- Measurement readout
- Protection and alarm settings
- Maintenance indicators

Environment
Ambient air temperature for operation : -25…70 °C
Ambient air temperature for storage : -40…85 °C

Packing Units
Unit Type of Package 1 : PCE
Number of Units in Package 1 : 1
Package 1 Height : 6.7 cm
Package 1 Width : 7.9 cm
Package 1 Length : 21.5 cm
Package 1 Weight : 449.0 g

Contractual warranty