Back to Top

1
Hi, Guest!
  • SCHNEIDER ELECTRIC
  • 59603 base unit S10UX for Sepam series 20 - 24…250 V - with basic UMI

59603 Base Unit S10UX For Sepam Series 20 - 24…250 V - With Basic UMI

Update Terakhir
:
04 / 10 / 2023
Min. Pembelian
:
1 Unit

Harga

CALL
PT. SURYA HAWILA PERKASA , founded in 2006 has been growing up to a leading one-stop soluton provider for intelligent electrical distribution and energy efficiency systems.

We gives the best solutions for Industrial Automation products and services, Electrical, consultant, training.

Detail 59603 Base Unit S10UX For Sepam Series 20 - 24…250 V - With Basic UMI

Base Unit

base unit S10UX for Sepam series 20 - 24…250 V - with basic UMI

Specifications

Main
Range of product : Sepam series 20
Device short name : S10UX
User machine interface type : Without

Complementary
UMI control :
- Alarm acknowledgement
- Sepam reset
Display resolution : 128 x 64 pixels
Number of key : 1
Local signalling :
- 2 LEDs for Sepam operating status (front face)
- 9 LEDs for indication of parameters (front face)
Output type :
- Annunciation relay: 100...240 V AC 47.5...63 Hz continuous current: 2 A breaking capacity: 1 A cos φ > 0.3
- Annunciation relay: 127 V DC continuous current: 2 A breaking capacity: 0.5 A L/R < 20 ms
- Annunciation relay: 220 V DC continuous current: 2 A breaking capacity: 0.15 A L/R < 20 ms
- Annunciation relay: 24 V DC continuous current: 2 A breaking capacity: 2 A L/R < 20 ms
- Annunciation relay: 48 V DC continuous current: 2 A breaking capacity: 1 A L/R < 20 ms
- Control relay: 100...240 V AC 47.5...63 Hz continuous current: 8 A breaking capacity: 5 A cos φ > 0.3 making capacity: < 15 A for 200 ms
- Control relay: 100...240 V AC 47.5...63 Hz continuous current: 8 A breaking capacity: 8 A resistive making capacity: < 15 A for 200 ms
- Control relay: 127 V DC continuous current: 8 A breaking capacity: 0.2 A L/R < 40 ms making capacity: < 15 A for 200 ms
- Control relay: 127 V DC continuous current: 8 A breaking capacity: 0.5 A L/R < 20 ms making capacity: < 15 A for 200 ms
- Control relay: 127 V DC continuous current: 8 A breaking capacity: 0.7 A resistive making capacity: < 15 A for 200 ms
- Control relay: 220 V DC continuous current: 8 A breaking capacity: 0.1 A L/R < 40 ms making capacity: < 15 A for 200 ms
- Control relay: 220 V DC continuous current: 8 A breaking capacity: 0.2 A L/R < 20 ms making capacity: < 15 A for 200 ms
- Control relay: 220 V DC continuous current: 8 A breaking capacity: 0.3 A resistive making capacity: < 15 A for 200 ms
- Control relay: 24 V DC continuous current: 8 A breaking capacity: 4 A L/R < 40 ms making capacity: < 15 A for 200 ms
- Control relay: 24 V DC continuous current: 8 A breaking capacity: 6 A L/R < 20 ms making capacity: < 15 A for 200 ms
- Control relay: 24 V DC continuous current: 8 A breaking capacity: 8 A resistive making capacity: < 15 A for 200 ms
- Control relay: 48 V DC continuous current: 8 A breaking capacity: 1 A L/R < 40 ms making capacity: < 15 A for 200 ms
- Control relay: 48 V DC continuous current: 8 A breaking capacity: 2 A L/R < 20 ms making capacity: < 15 A for 200 ms
- Control relay: 48 V DC continuous current: 8 A breaking capacity: 4 A resistive making capacity: < 15 A for 200 ms
[Us] rated supply voltage :
- 110/240 V AC 47.5...63 Hz tolerance: - 20...10 % deactivated consumption: < 6 VA maximum consumption: < 15 VA
- 24/250 V DC tolerance: - 20...10 % deactivated consumption: < 4.5 W maximum consumption: < 8 W
Supply inrush current :
< 10 A for 10 ms at 24/250 V DC
< 15 A at 110/240 V AC
Mounting mode : Fixed
Mounting support : Plate
Height : 222 mm
Width : 176 mm
Depth : 129 mm
Net weight : 1.2 kg
Power frequency dielectric withstand : 2 kV during 1 min conforming to IEC 60255-5
[Uimp] rated impulse withstand voltage : 5 kV (1.2/50 µs) conforming to IEC 60255-5
Mechanical robustness :
- Earthquakes in operation (level: 2) : 1 Gn (vertical axes) conforming to IEC 60255-21-3
- Earthquakes in operation (level: 2) : 2 Gn (horizontal axes) conforming to IEC 60255-21-3
- Jolts de-energized (level: 2) : 20 Gn/16 ms conforming to IEC 60255-21-2
- Shocks de-energized (level: 2) : 30 Gn/11 ms conforming to IEC 60255-21-2
- Shocks in operation (level: 2) : 10 Gn/11 ms conforming to IEC 60255-21-2
- Vibrations de-energized (level: 2) : 2 Gn, 10 Hz...150 Hz conforming to IEC 60255-21-1
- Vibrations in operation (level: 2) : 1 Gn, 10 Hz...150 Hz conforming to IEC 60255-21-1
- Vibrations in operation (level: Fc) : 2 Hz...13.2 Hz, a = +/- 1 mm conforming to IEC 60068-2-6

Environment
Standards :
- CSA C22.2 No 14-95
- CSA C22.2 No 0.17-00
- EN 50263
- UL 508
- CSA C22.2 No 94-M91
Product certifications :
- C22.2 file N° 210625
- UL 508 file N° 212533
- CE
Fire resistance : 650 °C conforming to IEC 60695-2-11
IP degree of protection :
Other panels: IP20 conforming to IEC 60529
Front panel: IP52 conforming to IEC 60529
NEMA degree of protection : Type 12 conforming to NEMA
Immunity to microbreaks : 10 ms
Electromagnetic compatibility :
- 1 MHz damped oscillating wave: (immunity tests-conducted disturbances), III, 2.5 kV MC, 1 kV MD, conforming to IEC 60255-22-1
- Fast transient bursts: (immunity tests-conducted disturbances), A or B, 4kV, 2.5 kHz/2 kV, 5 kHz, conforming to IEC 60255-22-4
- Fast transient bursts: (immunity tests-conducted disturbances), IV, 4kV, 2.5 kHz, conforming to IEC 61000-4-4
- Immunity to magnetic fields at network frequency: (immunity tests-radiated disturbances), IV, 30 A/m (continuous)-300 A/m (13 s), conforming to IEC 61000-4-8
Immunity to radiated fields: (immunity tests-radiated disturbances), III, 10 V/m, 80 MHz...2 GHz, conforming to IEC 61000-4-3
- Surges: (immunity tests-conducted disturbances), III, 2 kV MC, 1 kV MD, conforming to IEC 61000-4-5
- 1 MHz damped oscillating wave: (immunity tests-conducted disturbances), 2.5 kV MC and MD, conforming to ANSI C37.90.1
- 100 kHz damped oscillating wave: (immunity tests-conducted disturbances), 2.5 kV MC, 1 kV MD, conforming to IEC 61000-4-12
- Conducted disturbance emission: (emission tests), conforming to IEC 60255-25
- Conducted disturbance emission: (emission tests), B, conforming to EN 55022
- Disturbing field emission: (emission tests), conforming to IEC 60255-25
- Disturbing field emission: (emission tests), A, conforming to EN 55022
- Electrostatic discharge: (immunity tests-radiated disturbances), 8 kV air, 4 kV contact, conforming to ANSI C37.90.3
- Electrostatic discharge: (immunity tests-radiated disturbances), 8 kV air, 6 kV contact, conforming to IEC 60255-22-2
- Fast transient bursts: (immunity tests-conducted disturbances), 4kV, 2.5 kHz, conforming to ANSI C37.90.1
- Immunity to conducted RF disturbances: (immunity tests-conducted disturbances), 10 V, conforming to IEC 60255-22-6
- Immunity to radiated fields: (immunity tests-radiated disturbances), 10 V/m, 80 MHz...1 GHz, conforming to IEC 60255-22-3
- Immunity to radiated fields: (immunity tests-radiated disturbances), 35 V/m, 25 MHz...1 GHz, conforming to ANSI C37.90.2 (1995)
- Voltage interruptions: (immunity tests-conducted disturbances), 100 %, 10 ms, conforming to IEC 60255-11
Climatic withstand :
- Continuous exposure to damp heat (in operation) : Ca: 10 days, 93 % RH, 40 °C (104 °F) conforming to IEC 60068-2-3
- Continuous exposure to damp heat (in storage) : Ca: 56 days, 93 % RH, 40 °C (104 °F) conforming to IEC 60068-2-3
- Exposure to cold (in operation) : Ab: - 25 °C (- 13 °F) conforming to IEC 60068-2-1
- Exposure to cold (in storage) : Ab: - 25 °C (- 13 °F) conforming to IEC 60068-2-1
- Exposure to dry heat (in operation) : Bb: 70 °C (158 °F) conforming to IEC 60068-2-2
- Exposure to dry heat (in storage) : Bb: 70 °C (158 °F) conforming to IEC 60068-2-2
- Influence of corrosion/gaz test 2 (in operation) : C: 21 days, 75 % RH, 25 °C (- 13 °F), 0.5 ppm H2S, 1 ppm S02 conforming to IEC 60068-2-60
- Temperature variation with specified variation rate (in operation) : Nb: - 25 °C to 70 °C (- 13 °F to 158 °F) 5 °C/min (41 °F/min) conforming to IEC 60068-2-14
- Influence of corrosion/gaz test 4 (in operation) : 21 days, 75 % RH, 25 °C, 0.01 ppm H2S, 0.2 ppm S02, 0.02 ppm NO2, 0.01 ppm Cl2 conforming to IEC 60068-2-60
- Salt mist (in operation) : Kb/2 conforming to IEC 60068-2-52

Packing Units
Unit Type of Package 1 : PCE
Number of Units in Package 1 : 1
Package 1 Height : 12.6 cm
Package 1 Width : 26.6 cm
Package 1 Length : 26.7 cm
Package 1 Weight : 996.0 g
Unit Type of Package 2 : S03
Number of Units in Package 2 : 3
Package 2 Height : 30.0 cm
Package 2 Width : 30.0 cm
Package 2 Length : 40.0 cm
Package 2 Weight : 3.701 kg
Tampilkan Lebih Banyak
Kontak Kami