Back to Top

1
Hi, Guest!

59608 Remote Advanced UMI Module DSM303 Sepam Series 20, 40, 60, 80

Update Terakhir
:
03 / 10 / 2023
Min. Pembelian
:
1 Unit

Harga

CALL
PT. SURYA HAWILA PERKASA , founded in 2006 has been growing up to a leading one-stop soluton provider for intelligent electrical distribution and energy efficiency systems.

We gives the best solutions for Industrial Automation products and services, Electrical, consultant, training.

Detail 59608 Remote Advanced UMI Module DSM303 Sepam Series 20, 40, 60, 80

Remote Control

remote advanced UMI module DSM303 Sepam series 20, 40, 60, 80

Specifications

Main
Range of product :
- Sepam series 20
- Sepam series 40
- Sepam series 60
- Sepam series 80
Device short name : DSM303
User machine interface type : Remote advanced

Complementary
UMI indication :
- Sepam parameter setting
- Version of Sepam and remote modules
- Metering and diagnosis data
- Protection setting
- Alarms and operating messages
- Status of logic imputs
UMI control :
- Alarm acknowledgement
- Output testing
- Sepam reset
Local signalling :
- 2 LEDs for Sepam operating status (front face)
- 9 LEDs for indication of parameters (front face)
Height : 117 mm
Width : 152 mm
Depth : 40 mm
Net weight : 0.3 kg
Mechanical robustness :
- Earthquakes in operation (level: 2) : 1 Gn (vertical axes) conforming to IEC 60255-21-3
- Earthquakes in operation (level: 2) : 2 Gn (horizontal axes) conforming to IEC 60255-21-3
- Jolts de-energized (level: 2) : 20 Gn/16 ms conforming to IEC 60255-21-2
- Shocks de-energized (level: 2) : 27 Gn/11 ms conforming to IEC 60255-21-2
- Shocks in operation (level: 2) : 10 Gn/11 ms conforming to IEC 60255-21-2
- Vibrations de-energized (level: 2) : 2 Gn, 10 Hz...150 Hz conforming to IEC 60255-21-1
- Vibrations in operation (level: 2) : 1 Gn, 10 Hz...150 Hz conforming to IEC 60255-21-1
- Vibrations in operation (level: Fc) : 2 Hz...13.2 Hz, a = +/- 1 mm conforming to IEC 60068-2-6

Environment
IP degree of protection : IP52 conforming to IEC 60529
Electromagnetic compatibility :
- Fast transient bursts: (immunity tests-conducted disturbances), A and B, 4kV, 2.5 kHz/2 kV, 5 kHz, conforming to IEC 60255-22-4
- Fast transient bursts: (immunity tests-conducted disturbances), IV, 4kV, 2.5 kHz, conforming to IEC 61000-4-4
Immunity to conducted RF disturbances: (immunity tests-conducted disturbances), III, 10 V, conforming to IEC 60255-22-6
- Immunity to magnetic fields at network frequency: (immunity tests-radiated disturbances), IV, 30 A/m (continuous)-300 A/m (1-3 s), conforming to IEC 61000-4-8
- Immunity to radiated fields: (immunity tests-radiated disturbances), III, 10 V/m, 80 MHz...2 GHz, conforming to IEC 61000-4-3
- Surges: (immunity tests-conducted disturbances), III, 2 kV CM, 1 kV DM, conforming to IEC 61000-4-5
1 MHz damped oscillating wave: (immunity tests-conducted disturbances), 2.5 kV CM, 1 kV DM, conforming to IEC 60255-22-1
- 1 MHz damped oscillating wave: (immunity tests-conducted disturbances), 2.5 kV CM, 2.5 kV DM, conforming to ANSI C37.90.1
- 100 kHz damped oscillating wave: (immunity tests-conducted disturbances), 2.5 kV CM, 1 kV DM, conforming to IEC 61000-4-12
- Conducted disturbance emission: (emission tests), conforming to IEC 60255-25
- Conducted disturbance emission: (emission tests), A, conforming to EN 55022
- Disturbing field emission: (emission tests), conforming to IEC 60255-25
- Disturbing field emission: (emission tests), A, conforming to EN 55022
- Electrostatic discharge: (immunity tests-radiated disturbances), 8 kV air, 4 kV contact, conforming to ANSI C37.90.3
- Electrostatic discharge: (immunity tests-radiated disturbances), 8 kV air, 6 kV contact, conforming to IEC 60255-22-2
- Fast transient bursts: (immunity tests-conducted disturbances), 4kV, 2.5 kHz, conforming to ANSI C37.90.1
- Immunity to radiated fields: (immunity tests-radiated disturbances), 10 V/m, 80 MHz...1 GHz, conforming to IEC 60255-22-3
- Immunity to radiated fields: (immunity tests-radiated disturbances), 35 V/m, 25 MHz...1 GHz, conforming to ANSI C37.90.2
- Voltage interruptions: (immunity tests-conducted disturbances), 100 % during 100 ms, conforming to IEC 60255-11
Climatic withstand :
- Continuous exposure to damp heat (in operation) : Cab: 10 days, 93 % RH, 40 °C conforming to IEC 60068-2-78
- Continuous exposure to damp heat (in storage) : Cab: 56 days, 93 % RH, 40 °C conforming to IEC 60068-2-78
- Continuous exposure to damp heat (in storage) : Db: 6 days, 95 % RH, 55 °C conforming to IEC 60068-2-30
- Exposure to cold (in storage) : Ab: - 25 °C conforming to IEC 60068-2-1
- Exposure to dry heat (in operation) : Bd: 70 °C conforming to IEC 60068-2-2
- Exposure to dry heat (in storage) : Bb: 70 °C conforming to IEC 60068-2-2
- Salt mist (in operation) : Kb/2: 6 days conforming to IEC 60068-2-52
- Temperature variation with specified variation rate (in storage) : Nb: - 25 °C to 70 °C, 5 °C/min conforming to IEC 60068-2-14
- Influence of corrosion/gaz test 2 (in operation) : 21 days, 75 % RH, 25 °C, 0.5 ppm H2S, 1 ppm S02 conforming to IEC 60068-2-60
- Influence of corrosion/gaz test 4 (in operation) : 21 days, 75 % RH, 25 °C, 0.01 ppm H2S, 0.2 ppm S02, 0.2 ppm NO2, 0.01 ppm CI2 conforming to IEC 60068-2-60
Exposure to cold: Ad: - 25 °C conforming to IEC 60068-2-1

Packing Units
Unit Type of Package 1 : PCE
Number of Units in Package 1 : 1
Package 1 Height : 7.0 cm
Package 1 Width : 13.0 cm
Package 1 Length : 18.5 cm
Package 1 Weight : 341.0 g
Unit Type of Package 2 : S02
Number of Units in Package 2 : 8
Package 2 Height : 15.0 cm
Package 2 Width : 30.0 cm
Package 2 Length : 40.0 cm
Package 2 Weight : 2.927 kg
Tampilkan Lebih Banyak