Detail ATV660C31Q4X1 Variable Speed Drive, Altivar Process ATV600, Compact
Variable Speed Drive
Variable speed drive, Altivar Process ATV600, Compact System ATV660, 315/250 kW, 400 V, IP23
Spesifikasi
Main
Range of produc : Altivar Process ATV600
Product or component type : Variable speed drive
Product specific application : Process and utilities
Device short name : ATV660
Product destination :
- Synchronous motors
- Asynchronous motors
Assembly style : In floor-standing enclosure compact version
Provided equipment :
- Enclosure Spacial SF
- Graphical operating panel in the enclosure door
- Frequency inverter
- Main switch
- Line choke
- Terminal block main supply
- Terminal block motor
Cable entry : Bottom
Colour of enclosure : Light grey (RAL 7035)
IP degree of protection : IP23 conforming to IEC 61800-5-1
Type of cooling : Forced convection
[Us] rated supply voltage : 380...415 V - 10...6 %
Supply frequency : 50/60 Hz +/-5 %
Network number of phases : 3 phases
Overvoltage category : III
Asynchronous motor control profile :
- Variable torque standard
- Constant torque standard
- Optimized torque mode
Synchronous motor control profile : Permanent magnet motor
Output voltage : <= power supply voltage
Permissible temporary current boost :
1.1 x In during 60 s (normal duty)
1.5 x In during 60 s (heavy duty)
Nominal switching frequency : 2.5 kHz
Switching frequency : 2...8 kHz adjustable with derating factor
Speed drive output frequency : 0.1…500 Hz
Motor power kW :
- 315 kW for normal duty
- 250 kW for heavy duty
Continuous output current :
- 590 A at 2.5 kHz for normal duty
- 477 A at 2.5 kHz for heavy duty
Maximum transient current :
- 649 A during 60 s per 10 min (normal duty)
- 716 A during 60 s per 10 min (heavy duty)
Line current :
- 538 A at 400 V (normal duty)
- 432 A at 400 V (heavy duty)
Apparent power :
- 373 kVA at 400 V (normal duty)
- 299 kVA at 400 V (heavy duty)
Maximum THDI : <42 % full load conforming to IEC 61000-3-12
Short-circuit protection :
- Internal: 400.0 A 2 aR fuse
- Upstream: 630.0 A gG fuse (normal duty)
- Upstream: 500.0 A gG fuse (heavy duty)
Energy efficiency ratio : 0.98
Power dissipation in W :
- 7810 W, total (normal duty)
- 5700 W, total (heavy duty)
- 990 W, control part (normal duty)
- 680 W, control part (heavy duty)
Volume of cooling air :
- 140 m3/h for control
- 1160 m3/h for power
Noise level : 70 dB conforming to 86/188/EEC - physical agents (noise) directive
Prospective line Isc : 50 kA for 100 ms
Electrical connection :
- Removable screw terminals, clamping capacity: 0.5...1.5 mm² for control
- M12 bar for main supply
- M12 bar for motor
Motor recommanded cable cross section :
2 x (3 x 185 mm²) (normal duty)
3 x (3 x 120 mm²) (normal duty)
2 x (3 x 150 mm²) (heavy duty)
3 x (3 x 120 mm²) (heavy duty)
Width : 600 mm
Height : 2150 mm
Depth : 664 mm
Net weight : 400 kg
number of preset speeds : 16 preset speeds
communication port protocol : Modbus TCP
Modbus serial : EtherNet/IP
Option card :
Slot A: communication module, Profibus DP V1
Slot A: communication module, PROFINET
Slot A: communication module, DeviceNet
Slot A: communication module, Modbus TCP/EtherNet/IP
Slot A: communication module, CANopen daisy chain RJ45
Slot A: communication module, CANopen SUB-D 9
Slot A: communication module, CANopen screw terminals
Slot A/slot B: digital and analog I/O extension module
Slot A/slot B: output relay extension module
Safety function : STO (safe torque off), level SIL 3 for <= 100 ms
EMC filter :
- Integrated conforming to EN/IEC 61800-3, category C3, shielded cable with 50 m
- Integrated conforming to EN/IEC 61800-3, category C4, unshielded cable with 80 m
Complementary
Motor slip compensation :
- Can be suppressed
- Not available in permanent magnet motor law
- Automatic whatever the load
- Adjustable
Acceleration and deceleration ramps : Linear adjustable separately from 0.01 to 9000 s
S, U or customized
Braking to standstill : By DC injection
Protection type :
Motor: thermal protection
Motor: safe torque off
Motor: motor phase break
Drive: thermal protection
Drive: safe torque off
Drive: overheating
Drive: overcurrent (between output phases and earth)
Drive: overload (output)
Drive: short-circuit protection
Drive: motor phase break
Drive: overvoltage (DC bus)
Drive: line supply overvoltage
Drive: line supply undervoltage
Drive: line supply phase loss
Drive: overspeed
Drive: break on the control circuit
Drive: short-circuit protection with semi-conductor fuse (main supply)
Drive: fan monitoring
Frequency resolution :
- Display unit: 0.1 Hz
- Analog input: 0.012/50 Hz
Connector type :
- RJ45 (on the control block) for Modbus serial
- RJ45 (on the control block) for Ethernet IP/Modbus TCP
Physical interface : 2-wire RS 485 for Modbus serial
Transmission frame : RTU for Modbus serial
Transmission rate :
- 10/100 Mbit/s for Ethernet IP/Modbus TCP
- 4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial
Exchange mode : Half duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP
Data format : 8 bits, configurable odd, even or no parity for Modbus serial
Type of polarization : No impedance for Modbus serial
Number of addresses : 1…247 for Modbus serial
Method of access : Slave Modbus TCP
Supply :
- External supply for digital inputs: 24 V DC (10…30 V), <1.25 mA, protection type: overload and short-circuit protection
- Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection
- Internal supply for digital inputs and STO: 24 V DC (21…27 V), <200 mA, protection type: overload and short-circuit protection
Local signalling : LCD display unit front door operation function, status and configuration
analogue input number : 3
Analogue input type :
- AI1, AI2, AI3 software-configurable voltage: 0...10 V DC, impedance: 30 kOhm, resolution 12 bits
- AI1, AI2, AI3 software-configurable current: 0...20 mA, impedance: 250 Ohm, resolution 12 bits
Discrete input number : 8
Discrete input type :
- DI1...DI6 programmable, 24 V DC (<= 30 V), impedance: 3.5 kOhm
- DI5, DI6 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V)
- STOA, STOB safe torque off, 24 V DC (<= 30 V), impedance: > 2.2 kOhm
Input compatibility :
- DI1...DI6: discrete input level 1 PLC conforming to EN/IEC 61131-2
- DI5, DI6: discrete input level 1 PLC conforming to IEC 65A-68
- STOA, STOB: discrete input level 1 PLC conforming to EN/IEC 61131-2
Discrete input logic :
- Positive logic (source) (DI1...DI6), < 5 V (state 0), > 11 V (state 1)
- Negative logic (sink) (DI1...DI6), > 16 V (state 0), < 10 V (state 1)
- Positive logic (source) (DI5, DI6), < 0.6 V (state 0), > 2.5 V (state 1)
- Positive logic (source) (STOA, STOB), < 5 V (state 0), > 11 V (state 1)
analogue output number : 2
Analogue output type :
- Software-configurable voltage AQ1, AQ2: 0...10 V DC impedance 470 Ohm, resolution 10 bits
- Software-configurable current AQ1, AQ2: 0...20 mA, resolution 10 bits
Sampling duration :
2 ms +/- 0.5 ms (DI1...DI4) - discrete input
5 ms +/- 1 ms (DI5, DI6) - discrete input
5 ms +/- 1 ms (AI1, AI2, AI3) - analog input
10 ms +/- 1 ms (AQ1, AQ2) - analog output
Accuracy :
+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input
+/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output
Linearity error :
- AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input
- AQ1, AQ2: +/- 0.2 % for analog output
Relay output number : 3
Relay output type :
- Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles
- Configurable relay logic R2: sequence relay NO electrical durability 100000 cycles
- Configurable relay logic R3: sequence relay NO electrical durability 100000 cycles
Refresh time : Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms)
Minimum switching current : Relay output R1, R2, R3: 5 mA at 24 V DC
Maximum switching current :
- Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V AC
- Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DC
- Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC
- Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC
Isolation : Between power and control terminals
Environment
Insulation resistance : > 1 MOhm 500 V DC for 1 minute to earth
Operating position : Vertical +/- 10 degree
Electromagnetic compatibility :
- Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2
- Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3
- Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4
- 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5
- Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
Pollution degree : 2 conforming to EN/IEC 61800-5-1
Vibration resistance :
- 1.5 mm peak to peak (f= 3…10 Hz) conforming to IEC 60068-2-6
- 0.6 gn (f= 10…200 Hz) conforming to IEC 60068-2-6
- 3M3 conforming to IEC 60721-3-3
Shock resistance :
- 4 gn for 11 ms conforming to IEC 60068-2-27
- 3M2 conforming to IEC 60721-3-3
Relative humidity : 5…95 % without condensation conforming to IEC 60068-2-3
Ambient air temperature for operation :
- -10…0 °C without derating (with option enclosure heating)
- 0…40 °C without derating
- 40…50 °C with derating factor
Ambient air temperature for storage : -25…70 °C
Operating altitude :
- < 1000 m without derating
- 1000...2000 m with current derating 1 % per 100 m
- 2000...3800 m with current derating 1 % per 100 m for TT earthing system
- 2000...3800 m with current derating 1 % per 100 m for TN earthing system
- 2000...3800 m with current derating 1 % per 100 m for IT earthing system
- 3800...4800 m with current derating 1 % per 100 m for TT earthing system
- 3800...4800 m with current derating 1 % per 100 m for TN earthing system
Environmental characteristic :
- Chemical pollution resistance class 3C3 conforming to EN/IEC 60721-3-3
- Dust pollution resistance class 3S3 conforming to EN/IEC 60721-3-3
- Humidity resistant class 3K3 conforming to EN/IEC 60721-3-3
Standards :
- EN/IEC 60204-1
- EN/IEC 61800-2
- EN/IEC 61800-3
- EN/IEC 61800-5-1
Product certifications :
- ATEX
- EAC
- C-Tick
Marking : CE
Packing Units
Unit Type of Package 1 : PCE
Number of Units in Package 1 : 1
Package 1 Height : 215 cm
Package 1 Width : 66.9 cm
Package 1 Length : 60 cm
Package 1 Weight : 445 kg
Unit Type of Package 2 : CAR
Number of Units in Package 2 : 1
Package 2 Height : 230 cm
Package 2 Width : 80 cm
Package 2 Length : 75 cm
Package 2 Weight : 420 kg