Back to Top

1
Hi, Guest!
  • SCHNEIDER ELECTRIC
  • ATV680C11Q4X1 Variable speed drive, Altivar Process ATV600, Low Harmon

ATV680C11Q4X1 Variable Speed Drive, Altivar Process ATV600, Low Harmon

Update Terakhir
:
18 / 03 / 2024
Min. Pembelian
:
1 Unit

Harga

CALL
PT. SURYA HAWILA PERKASA , founded in 2006 has been growing up to a leading one-stop soluton provider for intelligent electrical distribution and energy efficiency systems.

We gives the best solutions for Industrial Automation products and services, Electrical, consultant, training.

Detail ATV680C11Q4X1 Variable Speed Drive, Altivar Process ATV600, Low Harmon

Variable Speed Drive

Variable speed drive, Altivar Process ATV600, Low Harmonic System ATV680, 110/90 kW, 400 V, IP23

Spesifikasi

Main
Device short name : ATV680
Product destination :
- Asynchronous motors
- Synchronous motors
IP degree of protection : IP23 conforming to IEC 61800-5-1
Supply frequency : 50/60 Hz +/- 5 %
Network number of phases : 3 phases
Range of produc : Altivar Process ATV600
Product or component type : Variable speed drive
Product specific application : Process and utilities
communication port protocol :
- EtherNet/IP
- Modbus TCP
- Modbus serial
[Us] rated supply voltage : 380...415 V - 10...6 %
Motor power kW :
- 110 kW for normal duty
- 90 kW for heavy duty

Complementary
Provided equipment :
- Enclosure Spacial SF
- Graphical operating panel in the enclosure door
- Main switch
- Semiconductor fuses
- Clean power filter with EMC filter
- Active infeed converter module
- Frequency inverter
- Terminal block main supply
- Terminal block motor
Colour of enclosure : Light grey (RAL 7035)
Type of cooling : Forced convection
Output voltage : <= power supply voltage
Permissible temporary current boost :
1.1 x In during 60 s (normal duty)
1.5 x In during 60 s (heavy duty)
Speed drive output frequency : 0.1…500 Hz
Speed accuracy :
- V/f mode: slip frequency
- VC without feedback: 0.3 x slip frequency
Continuous output current :
- 211 A at 2.5 kHz for normal duty
- 173 A at 2.5 kHz for heavy duty
Energy efficiency ratio : 0.965
Power dissipation in W :
- 4220 W, total (normal duty)
- 3480 W, total (heavy duty)
- 560 W, control part (normal duty)
- 470 W, control part (heavy duty)
Volume of cooling air :
- 1160 m3/h for power
- 140 m3/h for control
Prospective line Isc : 50 kA for 100 ms
Motor recommanded cable cross section :
1 x (3 x 120 mm²) (normal duty)
2 x (3 x 50 mm²) (normal duty)
1 x (3 x 95 mm²) (heavy duty)
Height : 2150 mm
Depth : 664 mm
Safety function : STO (safe torque off), level SIL 3 for <= 100 ms
Protection type :
Motor: thermal protection
Motor: safe torque off
Motor: motor phase break
Drive: thermal protection
Drive: safe torque off
Drive: overheating
Drive: overcurrent (between output phases and earth)
Drive: overload (output)
Drive: short-circuit protection
Drive: motor phase break
Drive: overvoltage (DC bus)
Drive: line supply overvoltage
Drive: line supply undervoltage
Drive: line supply phase loss
Drive: overspeed
Drive: break on the control circuit
Drive: short-circuit protection with semi-conductor fuse (main supply)
Drive: fan monitoring
Frequency resolution :
- Display unit: 0.1 Hz
- Analog input: 0.012/50 Hz
Connector type :
- RJ45 (on the control block) for Modbus serial
- RJ45 (on the control block) for Ethernet IP/Modbus TCP
Physical interface : 2-wire RS 485 for Modbus serial
Transmission frame : RTU for Modbus serial
Transmission rate :
- 10/100 Mbit/s for Ethernet IP/Modbus TCP
- 4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial
Exchange mode : Half duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP
Data format : 8 bits, configurable odd, even or no parity for Modbus serial
Type of polarization : No impedance for Modbus serial
Number of addresses : 1…247 for Modbus serial
Supply :
- External supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protection
- Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection
- Internal supply for digital inputs and STO: 24 V DC (21…27 V), <200 mA, protection type: overload and short-circuit protection
Local signalling : LCD display unit front door operation function, status and configuration
Input compatibility
- DI1...DI6: discrete input level 1 PLC conforming to EN/IEC 61131-2
- DI5, DI6: discrete input level 1 PLC conforming to IEC 65A-68
- STOA, STOB: discrete input level 1 PLC conforming to EN/IEC 61131-2
Discrete input logic :
- Positive logic (source) (DI1...DI6), < 5 V (state 0), > 11 V (state 1)
- Negative logic (sink) (DI1...DI6), > 16 V (state 0), < 10 V (state 1)
- Positive logic (source) (DI5, DI6), < 0.6 V (state 0), > 2.5 V (state 1)
- Positive logic (source) (STOA, STOB), < 5 V (state 0), > 11 V (state 1)
Sampling duration :
2 ms +/- 0.5 ms (DI1...DI4) - discrete input
5 ms +/- 1 ms (DI5, DI6) - discrete input
5 ms +/- 1 ms (AI1, AI2, AI3) - analog input
10 ms +/- 1 ms (AQ1, AQ2) - analog output
Accuracy :
+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input
+/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output
Linearity error :
- AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input
- AQ1, AQ2: +/- 0.2 % for analog output
Refresh time : Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms)
Isolation : Between power and control terminals
Insulation resistance : > 1 MOhm 500 V DC for 1 minute to earth
Relative humidity : 5…95 % without condensation conforming to IEC 60068-2-3
Option card :
Slot A: communication module, Profibus DP V1
Slot A: communication module, PROFINET
Slot A: communication module, DeviceNet
Slot A: communication module, Modbus TCP/EtherNet/IP
Slot A: communication module, CANopen daisy chain RJ45
Slot A: communication module, CANopen SUB-D 9
Slot A: communication module, CANopen screw terminals
Slot A/slot B: digital and analog I/O extension module
Slot A/slot B: output relay extension module
Discrete input number : 8
Discrete input type :
- DI1...DI6 programmable, 24 V DC (<= 30 V), impedance: 3.5 kOhm
- DI5, DI6 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V)
- STOA, STOB safe torque off, 24 V DC (<= 30 V), impedance: > 2200 kOhm
Discrete input logic : 16 preset speeds
analogue input number : 3
Analogue input type :
- AI1, AI2, AI3 software-configurable voltage: 0...10 V DC, impedance: 30 kOhm, resolution 12 bits
- AI1, AI2, AI3 software-configurable current: 0...20 mA, impedance: 250 Ohm, resolution 12 bits
analogue output number : 2
Analogue output type :
- Software-configurable voltage AQ1, AQ2: 0...10 V DC impedance 470 Ohm, resolution 10 bits
- Software-configurable current AQ1, AQ2: 0...20 mA, resolution 10 bits
Relay output number : 3
Relay output type :
- Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles
- Configurable relay logic R2: sequence relay NO electrical durability 100000 cycles
- Configurable relay logic R3: sequence relay NO electrical durability 100000 cycles
Maximum switching current :
- Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V AC
- Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DC
- Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC
- Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC
Minimum switching current : Relay output R1, R2, R3: 5 mA at 24 V DC
Method of access : Slave Modbus TCP
Asynchronous motor control profile :
- Variable torque standard
- Constant torque standard
- Optimized torque mode
Synchronous motor control profile : Permanent magnet motor
Acceleration and deceleration ramps :
- Linear adjustable separately from 0.01 to 9000 s
- S, U or customized
Motor slip compensation :
- Automatic whatever the load
- Adjustable
- Can be suppressed
- Not available in permanent magnet motor law
Switching frequency : 2...8 kHz adjustable with derating factor
Nominal switching frequency : 2.5 kHz
Braking to standstill : By DC injection
Line current :
- 175 A at 400 V (normal duty)
- 144 A at 400 V (heavy duty)
Apparent power :
- 121 kVA at 400 V (normal duty)
- 100 kVA at 400 V (heavy duty)
Maximum transient current :
- 232 A during 60 s per 10 min (normal duty)
- 260 A during 60 s per 10 min (heavy duty)
Short-circuit protection :
- Upstream: 250 A gG fuse (normal duty)
- Upstream: 250 A gG fuse (heavy duty)
- Internal: 250 A aR fuse
Electrical connection :
- Removable screw terminals, clamping capacity: 0.5...1.5 mm² for control
- M12 bar for main supply
- M12 bar for motor
Cable entry : Bottom
Width : 600 mm
Net weight : 400 kg

Environment
Noise level : 70 dB conforming to 86/188/EEC - physical agents (noise) directive
EMC filter :
- Integrated conforming to EN/IEC 61800-3, category C3, shielded cable with 50 m
- Integrated conforming to EN/IEC 61800-3, category C4, unshielded cable with 80 m
Pollution degree : 2 conforming to EN/IEC 61800-5-1
Vibration resistance :
- 1.5 mm peak to peak (f= 3…10 Hz) conforming to IEC 60068-2-6
- 0.6 gn (f= 10…200 Hz) conforming to IEC 60068-2-6
- 3M3 conforming to IEC 60721-3-3
Shock resistance :
- 4 gn for 11 ms conforming to IEC 60068-2-27
- 3M2 conforming to IEC 60721-3-3
Operating altitude :
< 1000 m without derating
1000...2000 m with current derating 1 % per 100 m
2000...3800 m with current derating 1 % per 100 m for TT earthing system
2000...3800 m with current derating 1 % per 100 m for TN earthing system
2000...3800 m with current derating 1 % per 100 m for IT earthing system
3800...4800 m with current derating 1 % per 100 m for TT earthing system
3800...4800 m with current derating 1 % per 100 m for TN earthing system
Environmental characteristic :
- Chemical pollution resistance class 3C3 conforming to EN/IEC 60721-3-3
- Dust pollution resistance class 3S3 conforming to EN/IEC 60721-3-3
- Humidity resistant class 3K3 conforming to EN/IEC 60721-3-3
Product certifications :
- ATEX
- C-Tick
- EAC
Operating position : Vertical +/- 10 degree
Marking : CE
Standards :
- EN/IEC 60204-1
- EN/IEC 61800-2
- EN/IEC 61800-3
- EN/IEC 61800-5-1
Maximum THDI : <5 % full load conforming to IEC 61000-3-12
Assembly style : In floor-standing enclosure low harmonic version
Electromagnetic compatibility :
- Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2
- Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3
- Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4
- 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5
- Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
Overvoltage category : III
Ambient air temperature for operation :
-10…0 °C without derating (with option enclosure heating)
0…40 °C without derating
40…50 °C with derating factor
Ambient air temperature for storage : -25…70 °C

Packing Units
Unit Type of Package 1 : PCE
Number of Units in Package 1 : 1
Package 1 Height : 215 cm
Package 1 Width : 66.9 cm
Package 1 Length : 60 cm
Package 1 Weight : 445 kg
Unit Type of Package 2 : CAR
Number of Units in Package 2 : 1
Package 2 Height : 230 cm
Package 2 Width : 80 cm
Package 2 Length : 75 cm
Package 2 Weight : 445 kg
Tampilkan Lebih Banyak
Kontak Kami