Back to Top

1
Hi, Guest!
  • DIXELL
  • DIXELL DIGITAL CONTROLLERS IC110CX-11200 EMERSON

DIXELL DIGITAL CONTROLLERS IC110CX-11200 EMERSON

Update Terakhir
:
13 / 07 / 2020
Min. Pembelian
:
1 Unit

Harga

CALL
PT. SURYA HAWILA PERKASA , founded in 2006 has been growing up to a leading one-stop soluton provider for intelligent electrical distribution and energy efficiency systems.

We gives the best solutions for Industrial Automation products and services, Electrical, consultant, training.

Detail DIXELL DIGITAL CONTROLLERS IC110CX-11200 EMERSON

DIXELL DIGITAL CONTROLLERS IC110CX-11200
ADVANCED MULTIFUNCTION CONTROLLERS FOR CHILLERS WITH 1 CIRCUIT AND 1 COMPRESSOR 

Specifications
Generals: Display: dual with icons
Power supply: 12, 24Vac/dc
Probe inputs: Pb1: NTC - Pb2: NTC - Pb3: NTC, 4÷20mA, 0÷5V configurable - Pb4: NTC, DI configurable
Digital inputs: HP: present - LP: present - N° 4: configurable
Relay outputs: RL1 Compressor 1: *8A - RL2: *8A configurable - RL3: *8A configurable - RL4: *8A configurable - RL5: *8A configurable, optional
Other outputs: Hot Key / Prog Tool Kit / TTL output: present - Analogs: 4÷20mA/0÷10V optional - Signal for fan speed control: °PWM - Voltage output for external relay: 12Vdc-40mA max
Other: Triac output: 2A optional - Remote display output: 1 x VICX610 - Real time clock: optional - Buzzer: optional
Display: 4 digits, red LED 8.5mm high4 digits, yellow LED 7.5mm high
Data storing: on the non-volatile memory (EEPROM)
Operating temperature: -10÷60°C
Storage temperature: -30÷85°C
Relative humidity: 20÷85% (no condensing)
Measuring and regulation range: pressure probe: 0÷50bar NTC probe: -50÷110°C
Note
* With triac module: RL1 = 5A - RL2 = 5A - RL4 = 5A config - RL5 = not present
Note
* The PWM output is substituted with the output for the external relay driver when the triac is inside
Features

  • Twin compressor functioning
  • Function of compressor capacity stages for high and low condensing pressure
  • ON/OFF or variable speed condensing fan control without the need to use external devices
  • Forced and combined defrost
  • Energy-saving for time band or digital contact
  • Internal data logger with up to 50 alarms
  • Real-time clock
  • Voltage output for additional external relay management
  • Analog input configurable as NTC, 4÷20mA and 0÷5V ratiometric
  • Configurable relays, probes, and digital inputs
  • Hot Key for quick and easy programming
  • Serial connection to monitoring systems
Tampilkan Lebih Banyak