Back to Top

1
Hi, Guest!

EZC100H3035 PTCCB_ODA_PHOTO_Integration

Update Terakhir
:
16 / 06 / 2023
Min. Pembelian
:
1 Unit

Harga

CALL
PT. SURYA HAWILA PERKASA , founded in 2006 has been growing up to a leading one-stop soluton provider for intelligent electrical distribution and energy efficiency systems.

We gives the best solutions for Industrial Automation products and services, Electrical, consultant, training.

Detail EZC100H3035 PTCCB_ODA_PHOTO_Integration

Air Circuit Breaker

Specifications

Main
Range of product : EasyPact
Product or component type : Circuit breaker
Device short name : Easypact EZC100H
Circuit breaker name : Easypact EZC100H
Device application : Distribution
Poles description : 3P
Protected poles description : 3t
Network type :
- DC
- AC
Network frequency : 50/60 Hz
[In] rated current : 35 A at 40 °C
[Ui] rated insulation voltage : 690 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage : 6 kV conforming to IEC 60947-2
[Ue] rated operational voltage :
- 550 V AC 50/60 Hz conforming to IEC 60947-2
- 250 V DC conforming to IEC 60947-2
Breaking capacity code : H
Breaking capacity :
- 10 kA Icu at 125 V DC 1P conforming to IEC 60947-2
- 10 kA Icu at 250 V DC 2P conforming to IEC 60947-2
- 10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2
- 100 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2
- 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
- 50 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2
- 30 kA Icu at 380...400 V AC 50/60 Hz conforming to IEC 60947-2
- 30 kA Icu at 415 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service breaking capacity :
- 5 kA at 125 V DC conforming to IEC 60947-2
- 5 kA at 250 V DC conforming to IEC 60947-2
- 5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
- 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2
- 15 kA at 380...400 V AC 50/60 Hz conforming to IEC 60947-2
- 25 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2
- 50 kA at 110...130 V AC 50/60 Hz conforming to IEC 60947-2
- 7.5 kA at 415 V AC 50/60 Hz conforming to IEC 60947-2
Suitability for isolation : Yes conforming to IEC 60947-2
Utilisation category : Category A
Trip unit name : TM-D
Trip unit technology : Thermal-magnetic
Trip unit rating : 35 A at 50 °C
Protection type :
- Overload protection
- Short-circuit protection
Pollution degree : 3 conforming to IEC 60947

Complementary
Control type : Toggle
Mounting mode : Fixed
Mounting support : Backplate
upside connection : Front
Downside connection : Front
Mechanical durability : 8500 cycles
Electrical durability : Category A: 1500 cycles 415 V AC 50/60 Hz conforming to IEC 60947-2
Connection pitch : 25 mm
Local signalling : Positive contact indication
Neutral protection setting : Without protection
Earth-leakage protection : Without
Height : 130 mm
Width : 75 mm
Depth : 60 mm

Environment
Standards :
- EN/IEC 60947-1
- JIS C8201-2-2
- EN/IEC 60947-2
- GB/T 14048.2
IP degree of protection : IP20 conforming to IEC 60529
IK degree of protection : IK07 conforming to EN 50102
Ambient air temperature for operation : -25…70 °C
Ambient air temperature for storage : -35…85 °C

Packing Units
Unit Type of Package 1 : PCE
Number of Units in Package 1 : 1
Package 1 Height : 9.5 cm
Package 1 Width : 14 cm
Package 1 Length : 8.5 cm
Package 1 Weight : 819 g
Unit Type of Package 2 : S01
Number of Units in Package 2 : 6
Package 2 Height : 15 cm
Package 2 Width : 15 cm
Package 2 Length : 40 cm
Package 2 Weight : 4914 g
Unit Type of Package 3 : S02
Number of Units in Package 3 : 12
Package 3 Height : 15 cm
Package 3 Width : 30 cm
Package 3 Length : 40 cm
Package 3 Weight : 9828 g

Contractual warranty
Warranty : 12 months
Tampilkan Lebih Banyak
Kontak Kami