Detail GVSUPS60KB5HS Galaxy VS UPS 60kW 400V, 3 Internal 9Ah Smart Modular
UPS (Uninterruptible Power Supply)
Galaxy VS UPS 60kW 400V, 3 internal 9Ah smart modular battery strings, expandable to 5, Start-up 5x8
Specifications
Overview
Presentation : Highly efficient, easy-to-deploy 60kW, 400V 3-phase UPS that brings best-in-class power protection and low total cost of ownership to edge, small and medium data centers, as well as to critical infrastructure in commercial and industrial applications. Includes 5x8 start-up service and 3 smart modular high capacity battery strings, expandable to 5 strings for extended runtime. See the battery runtime chart for details.
Lead time : Usually Ships within 2 Weeks
Main
Main Input Voltage : 400 V 3 phases
Other Input Voltage :
- 380 V
- 415 V
Main Output Voltage : 400 V 3 phases
Other Output Voltage :
- 380 V
- 415 V
Rated power in W : 60 kW
Rated power in VA : 60 kVA
Battery type :
- Internal modular battery
- VRLA
Provided equipment :
- Dust filter
- Installation manual
- Integrated network management
- Battery modules ship installed
- Start-up service
- EcoStruxure Ready
Batteries & Runtime
Efficiency : View Efficiency Graphaction_new_window
battery voltage : 480 V
Discharge battery voltage : 384 V
Max current discharge : 163 A
Battery power in VAH : 0 VAh runtime
Extended runtime : 0
General
Redundant : No
Physical
Colour : White
Height : 197 cm
Width : 55 cm
Depth : 84.7 cm
Net weight : 665 kg
USB compatible : No
Input
Network frequency : 40...70 Hz
Input voltage limits : 340...460 V 400 V
Maximum input current : 108 A
Max short time withstand current : 65 kA
Input harmonic distortion : Less than 3 % for full load
Load power factor : From 0.7 leading to 0.7 lagging without any derating
Input Power Factor at Full Load : 0.99
Output
Maximum configurable power in W : 60 kW
Harmonic distortion : Less than 3 %
Output frequency :
50 Hz sync to mains
60 Hz sync to mains
Crest factor : 2.5
Wave type : Sine wave
Output voltage tolerance :
+/- 5% after 2ms
+/-1% after 50ms
Output harmonic distortion : < 1% linear load and < 3% non-linear load
Output overload operation : 10 minutes at 125% and 60 seconds at 150%
bypass type : Built-in static bypass
Maximum configurable power in VA : 60 kVA
Conformance
Standards :
- IEC 62040-1-1
- IEC 62040-2
- OSHPD
Environmental
Ambient air temperature for operation : 0…40 °C
Relative humidity : 0…95 % non-condensing
Operating altitude : 0...3300 ft
Ambient air temperature for storage : -15…40 °C
Storage Relative Humidity : 10…80 % non-condensing
Storage altitude : 0.00…3048.00 m
Acoustic level : 54 dBA
Heat dissipation : 7103 Btu/h
IP degree of protection : IP20
Communications & Management
control panel : Touch screen LCD user interface
Packing Units
Unit Type of Package 1 : PCE
Number of Units in Package 1 : 1
Package 1 Height : 208.2 cm
Package 1 Width : 101 cm
Package 1 Length : 75.5 cm
Package 1 Weight : 270 kg
Contractual warranty
Warranty : 1 year on-site repair or replace with factory authorized Start-Up
Tampilkan Lebih Banyak