Back to Top

1
Hi, Guest!
  • SCHNEIDER ELECTRIC
  • LC7K0610M7 Contactor, TeSys K, 3P, AC-3/AC-3e,440V 6A, aux. 1NO, 220.

LC7K0610M7 Contactor, TeSys K, 3P, AC-3/AC-3e,440V 6A, Aux. 1NO, 220.

Update Terakhir
:
09 / 08 / 2023
Min. Pembelian
:
1 Unit

Harga

CALL
PT. SURYA HAWILA PERKASA , founded in 2006 has been growing up to a leading one-stop soluton provider for intelligent electrical distribution and energy efficiency systems.

We gives the best solutions for Industrial Automation products and services, Electrical, consultant, training.

Detail LC7K0610M7 Contactor, TeSys K, 3P, AC-3/AC-3e,440V 6A, Aux. 1NO, 220.

Contactor ABB AX185-30

Contactor, TeSys K, 3P, AC-3/AC-3e,440V 6A, aux. 1NO, 220...230V AC coil

Spesifikasi

Main
Range : TeSys
Product or component type : Contactor
Product name : TeSys K
device short name : LC7K
Device application : Control
Contactor application : Motor control

Complementary
Utilisation category :
- AC-3
- AC-4
- AC-3e
Poles description : 3P
power pole contact composition : 3 NO
[Ue] rated operational voltage :
- Power circuit: 690 V AC 50/60 Hz
- Signalling circuit: <= 690 V AC 50/60 Hz
[Ie] rated operational current :
- 6 A at <= 440 V AC AC-3 for power circuit
- 6 A at <= 440 V AC AC-3e for power circuit
Control circuit type : AC at 50/60 Hz silent
[Uc] control circuit voltage : 220...230 V AC 50/60 Hz
Motor power kW :
- 1.5 kW at 220...230 V AC 50/60 Hz AC-3
- 2.2 kW at 380...415 V AC 50/60 Hz AC-3
- 3 kW at 440 V AC 50/60 Hz AC-3
- 3 kW at 480 V AC 50/60 Hz AC-3
- 3 kW at 500...600 V AC 50/60 Hz AC-3
- 3 kW at 660...690 V AC 50/60 Hz AC-3
- 1.5 kW at 400 V AC 50/60 Hz AC-4
- 1.5 kW at 220...230 V AC 50/60 Hz AC-3e
- 2.2 kW at 380...415 V AC 50/60 Hz AC-3e
- 3 kW at 440 V AC 50/60 Hz AC-3e
- 3 kW at 480 V AC 50/60 Hz AC-3e
- 3 kW at 500...600 V AC 50/60 Hz AC-3e
- 3 kW at 660...690 V AC 50/60 Hz AC-3e
Auxiliary contact composition : 1 NO
[Uimp] rated impulse withstand voltage : 8 kV
Overvoltage category : III
[Ith] conventional free air thermal current :
- 20 A (at 50 °C) for power circuit
- 10 A (at 50 °C) for signalling circuit
Irms rated making capacity :
- 110 A AC for power circuit conforming to NF C 63-110
- 110 A AC for power circuit conforming to IEC 60947
- 110 A AC for signalling circuit conforming to IEC 60947
Rated breaking capacity :
- 110 A at 415 V conforming to IEC 60947
- 110 A at 440 V conforming to IEC 60947
- 80 A at 500 V conforming to IEC 60947
- 110 A at 220...230 V conforming to IEC 60947
- 110 A at 380...400 V conforming to IEC 60947
- 70 A at 660...690 V conforming to IEC 60947
[Icw] rated short-time withstand current :
- 90 A 50 °C - 1 s for power circuit
- 85 A 50 °C - 5 s for power circuit
- 80 A 50 °C - 10 s for power circuit
- 60 A 50 °C - 30 s for power circuit
- 45 A 50 °C - 1 min for power circuit
- 40 A 50 °C - 3 min for power circuit
- 20 A 50 °C - >= 15 min for power circuit
- 80 A - 1 s for signalling circuit
- 90 A - 500 ms for signalling circuit
- 110 A - 100 ms for signalling circuit
Associated fuse rating :
- 25 A gG at <= 440 V for power circuit
- 25 A aM for power circuit
- 10 A gG for signalling circuit conforming to IEC 60947
- 10 A gG for signalling circuit conforming to VDE 0660
Average impedance : 3 mOhm - Ith 20 A 50 Hz for power circuit
[Ui] rated insulation voltage :
- Power circuit: 600 V conforming to UL 508
- Power circuit: 690 V conforming to IEC 60947-4-1
- Signalling circuit: 690 V conforming to IEC 60947-4-1
- Signalling circuit: 690 V conforming to IEC 60947-5-1
- Signalling circuit: 600 V conforming to UL 508
- Power circuit: 600 V conforming to CSA C22.2 No 14
- Signalling circuit: 600 V conforming to CSA C22.2 No 14
Insulation resistance : > 10 MOhm for signalling circuit
Inrush power in VA : 3 VA (at 20 °C)
Hold-in power consumption in VA : 3 VA (at 20 °C)
Heat dissipation : 3 W
Control circuit voltage limits :
- Operational: 0.85...1.1 Uc (at <50 °C)
- Drop-out: 0.1...0.75 Uc (at <50 °C)
Connections - terminals :
- Screw clamp terminals 1 cable(s) 1.5…4 mm²solid
- Screw clamp terminals 1 cable(s) 0.75…4 mm²flexible without cable end
- Screw clamp terminals 1 cable(s) 0.34…2.5 mm²flexible with cable end
- Screw clamp terminals 2 cable(s) 1.5…4 mm²solid
- Screw clamp terminals 2 cable(s) 0.75…4 mm²flexible without cable end
- Screw clamp terminals 2 cable(s) 0.34…1.5 mm²flexible with cable end
Maximum operating rate : 3600 cyc/h
Auxiliary contacts type : Type instantaneous 1 NO
Signalling circuit frequency : <= 400 Hz
Minimum switching current : 5 mA for signalling circuit
Minimum switching voltage : 17 V for signalling circuit
Mounting support :
- Plate
- Rail
Tightening torque :
- 0.8…1.3 N.m - on screw clamp terminals Philips No 2
- 0.8…1.3 N.m - on screw clamp terminals flat Ø 6 mm
- 0.8…1.3 N.m - on screw clamp terminals pozidriv No 2
Operating time :
- 30...40 ms coil energisation and NO closing
- 30 ms coil de-energisation and NO opening
Safety reliability level
- B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
- B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Non overlap distance : 0.5 mm
Mechanical durability : 10 Mcycles
Electrical durability :
- 1.3 Mcycles 6 A AC-3 at Ue <= 440 V
- 1.3 Mcycles 6 A AC-3e at Ue <= 440 V
Mechanical robustness :
- Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
- Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27
- Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27
- Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27
- Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
- Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
- Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6
- Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
Depth : 57 mm
Product weight : 0.225 kg

Environment
Standards :
- EN/IEC 60947-4-1
- GB/T 14048.4
- UL 60947-4-1
- CSA C22.2 No 60947-4-1
- JIS C8201-4-1
Product certifications :
- CB Scheme
- CCC
- UL
- CSA
- EAC
- CE
- UKCA
IP degree of protection : IP2X conforming to VDE 0106
Protective treatment :
- TC conforming to IEC 60068
- TC conforming to DIN 50016
Ambient air temperature for storage : -50…80 °C
Operating altitude : 2000 m without derating
Flame retardance :
- V1 conforming to UL 94
- Requirement 2 conforming to NF F 16-101
- Requirement 2 conforming to NF F 16-102

Packing Units
Unit Type of Package 1 : PCE
Number of Units in Package 1 : 1
Package 1 Height : 6.5 cm
Package 1 Width : 6.2 cm
Package 1 Length : 5.0 cm
Package 1 Weight : 218.0 g
Unit Type of Package 2 : S02
Number of Units in Package 2 : 40
Package 2 Height : 15.0 cm
Package 2 Width : 30.0 cm
Package 2 Length : 40.0 cm
Package 2 Weight : 9.175 kg

Contractual warranty
Warranty : 18 months
Tampilkan Lebih Banyak
Kontak Kami