Detail REL52001 Easergy P3U30, 4L, 4U, 16DI/8DO, Uaux: 48 - 230V, DI: 220-23
Protection Relay
Easergy P3U30, 4L, 4U, 16DI/8DO, Uaux: 48 - 230V, DI: 220-230V, 2 x RJ-45
Specifications
arrow2_down
Main
Range of product : Easergy P3
Product or component type : Protection relay
Relay application : Universal
product reference : P3U30-5AAA3BCAA
power supply ; 48...230 V AC/DC
measuring inputs
: 1/5 A CT phase current 3
: 1/5 A CT residual current 1
: 100 V/110 V VT voltage 4
Number of sensors :
0 temperature sensor(s)
0 arc sensor(s)
number of Digital Inputs (DI) : 16
number of Digital Outputs (DO) :
1 watchdog
8
number of analogue inputs : 0
number of analogue outputs : 0
communication ports :
- USB port 1 front
- RJ45 2 rear
communication protocols :
- IEC 61850 ed. 1
- IEC 61850 ed. 2
- IEC 60870-5-101
- DNP3 TCP
- Modbus TCP
- EtherNet/IP
Redundancy communication port protocol :
- RSTP
- PRP
cybersecurity :
- Port hardening
- Password protection
protection functions :
- Phase overcurrent 50/51
- Directional phase overcurrent 67
- Earth fault overcurrent 50N/51N
-Directional earth fault 67N
- Transient earth fault 67NI
- Capacitor bank unbalance 51C
- Broken conductor 46 I2/I1
- Cold load pick-up
- Switch ON to fault (SOTF)
- Breaker failure 50BF
- Directional active underpower 37P
- Fault locator 21FL
- Recloser 79
- Phase undercurrent 37
- Excessive starting time, locked rotor 48/51LR
- Motor restart inhibition 66
- Capacitor overvoltage 59C
- Negative sequence overcurrent 46
- Overvoltage 59
- Undervoltage 27
- Positive sequence undervoltage 27P
- Earth fault overvoltage 59N
- Underfrequency 81/81N
- Rate of change of frequency 81R
- Synchro-check 25
- Lockout relay 86
- CT supervision 60
- VT supervision 60
- H2 detection 68H2
- H5 detection 68H5
- Programmable stages 99
- H5 detection
- Programmable curve
Arc flash protection : No
measurement functions :
- Current 3-phase
- Current zero sequence
- Current positive sequence
- Current negative sequence
- Current ratio of negative and positive
- Voltage phase to earth
- Voltage phase to phase
- Voltage zero sequence
- Voltage positive sequence
- Voltage negative sequence
- Voltage ratio of negative and positive
- Short circuit fault reactance
- Fault location current
- Earth fault reactance
- Frequency
- Active power
- RMS active power
- Reactive power
- RMS reactive power
- Apparent power
- RMS apparent power
- Active energy
- Reactive energy
- Cos φ
- Tan φ
- Power angle
- Power factor
- Voltage phasor diagram view
- Current phasor diagram view
- Current 2nd, 15th harmonics with THD
- Voltage 2nd, 15th harmonics with THD
- Voltage interruption
- Condition monitoring CB wear
control functions :
- Switchgear control and monitoring
- Programmable switchgear interlocking
- Local control on single-line diagram
- Local control with I/O keys
- Local/remote control
- 2 function keys
- Mobile application with Easergy SmartApp
- Web-server
- Programmable logic
controllable switchgear devices : 4 controlled + 8 displayed
number of setting groups : 4
monitoring functions :
- Trip circuit supervision 74
- Circuit breaker monitoring
- Relay self-monitoring
logs and records :
- Event recording
- Disturbance recording
- Tripping context
Switchgear diagnosis type :
- CT/VT supervision ANSI code: 60
- CT supervision
- Trip circuit supervision ANSI code: TCS
Connections - terminals :
- Screw removable (digital input/output)
- Pin removable (current transformer)
- Pin removable (voltage transformer)
Complementary
Operating threshold : 220...230 V AC/DC
Time synchronisation protocol : SNTP
Web server : Embedded HTTP server
Software name :
- EcoStruxure Power Device
- ESetup Easergy Pro
Display type : And LCD 128 x 64 pixels with single line diagram
Number of key : 2 customizable
Local signal ling :
4 LEDs
8 LEDs programmable
Standards : IEC
Height : 169.5 mm
Width : 170 mm
Depth : 205 mm
Net weight : 2.5 kg maximum
Environment
Electromagnetic compatibility :
- Emission tests conforming to IEC/EN 60255-26 ed. 3
- Emission tests class A conforming to CISPR 11
- Emission tests class A conforming to CISPR 22
- EMC immunity conforming to IEC/EN 60255-26 ed. 3
- EMC immunity conforming to EN/IEC 61000-4-18
- EMC immunity level 4 conforming to EN/IEC 61000-4-2
- EMC immunity level 3 conforming to EN/IEC 61000-4-3
- EMC immunity level 4 conforming to EN/IEC 61000-4-4
- EMC immunity level 3 conforming to EN/IEC 61000-4-5
- EMC immunity level 3 conforming to EN/IEC 61000-4-6
- EMC immunity conforming to EN/IEC 61000-4-8
- EMC immunity level 5 conforming to EN/IEC 61000-4-9
- EMC immunity conforming to EN/IEC 61000-4-29
- EMC immunity conforming to EN/IEC 61000-4-11
- EMC immunity conforming to EN/IEC 61000-4-17
- Mechanical robustness
- Vibrations (level: class II) conforming to IEC 60255-21-1
- Vibrations: Fc conforming to IEC 60068-2-6
- Shocks (level: class II) conforming to IEC 60255-21-2
- Shocks: Ea conforming to IEC 60068-2-27
- Seismic tests method A (level: class II) conforming to IEC 60255-21-3
- Bumps (level: class II) conforming to IEC 60255-21-2
- Bumps: Ea conforming to IEC 60068-2-27
climatic withstand :
- Exposure to dry heat Bb tests conforming to EN/IEC 60068-2-2
- Exposure to cold Ad tests conforming to EN/IEC 60068-2-1
- Exposure to damp heat in service Db tests conforming to EN/IEC 60068-2-30
- Exposure to damp heat in service Cab tests conforming to EN/IEC 60068-2-78
Ambient air temperature for operation : -40…65 °C
Ambient air temperature for storage : -40…70 °C
IP degree of protection : IP54 conforming to IEC 60529
Relative humidity : 0…95 %, without condensation
maximum operating altitude : 2000 m
Protective treatment : Conformal coating
Packing Units
Unit Type of Package 1 : PCE
Number of Units in Package 1 : 1
Package 1 Height : 26 cm
Package 1 Width : 21.5 cm
Package 1 Length : 31.5 cm
Package 1 Weight : 3.148 kg
Contractual warranty
Warranty : Up to 10 years extended warranty (Standard warranty 2 years. Please check with your local SE representative for extended warranty availability and conditions)
Tampilkan Lebih Banyak